Pr-Mode
related input setup as below:
Input
Signal name
Symbol
Setup value
Normally open
Normally closed
Trigger command
CTRG
20h
A0h
Homing signal
HOME
21h
A1h
Forced stop
STP
22h
A2h
Forward direction JOG
JOG+
23h
A3h
Opposite direction JOG
JOG-
24h
A4h
Forward limit
PL
25h
A5h
Reverse limit
NL
26h
A6h
Homing signal
ORG
27h
A7h
Road strength address 0
ADD0
28h
A8h
Road strength address 1
ADD1
29h
A9h
Road strength address 2
ADD2
2ah
Aah
Road strength address 3
ADD3
2bh
Abh
Torque switching
TC-SEL
09h
89h
Note:
CTRG, HOME is edge triggered, but the valid level must be last more than 1ms.
I/O input digital filtering
Pr5.15*
Name
I/F reading filter
Mode
P
S
T
Range
0~255
Unit
0.1ms
Default
0
Data Type
16bit
Access
R/W
Address
051FH
Repower
o
I/O input digital filtering; higher setup will arise control delay.
4.3.2 Switch Output Interface
Figure 4.4 Switch Output Interface
(1)
The user provide the external power supply . However, if current polarity connects reversely,
servo driver is damaged.
(2)
The output of the form is open-collector, the maximum voltage is 25V, and maximum current is
50mA. Therefore, the load of switch output signal must match the requirements. If you exceed the
requirements or output directly connected with the power supply, the servo drive is damaged.
(3)
If the load is inductive loads relays, etc., there must be anti-parallel freewheeling diode across
the load. If the freewheeling diode is connected reversely, the servo drive is damaged.
(4)
32
、
33
、
34
、
35
、
31 Pin
:
Single-ended output;
18
、
19 Pin
,
20
、
21 Pin
:
Differencial output.