User Manual Of ELP AC Servo
127
www.leadshine.com
Err153
Replace
battery
,
power-on
Alarm clear
?
Return to home
point
,
set Pr0.15=9
Alarm clear
YES
NO
Absolute
Encoder
NO
YES
Replace encoder
or set P0.15=0
8.11 Other functions
8.11.1 Zero speed output
(
ZSP
)
This function can be configured by IO output function parameters, as described in IO Pr4.10 parameters.
When the enabling and time meet the setting conditions, the corresponding output IO port set can output ON
Pr4.34
Name
Zero-speed
Mode
P
S
T
Range
10~20000
Unit
r/min
Default
50
Data Type
16bit
Access R/W
Address
0445H
Repower
-
You can set up the timing to feed out the
zero-speed detection output signal(ZSP
or TCL) in rotate speed (r/min).
The zero-speed detection signal(ZSP)
will be fed out when the motor speed
falls below the setup of this parameter,
Pr4.34
The setup of pr4.34 is valid for both
positive and negative direction
regardless of the motor rotating direction.
There is hysteresis of 10[r/min]