User Manual for ELP Servo
www.leadshine.com
160
Range
0~6
Unit
—
Default
2
Data Type
16bit
Access
R/W
Address
053DH
Repower
-
You can set up the communication speed of RS485.
Setup
value
Baud rate Setup
value
Baud rate
0
2400bps
4
38400bps
1
4800bps
5
57600bps
2
9600bps
6
115200bps
3
19200bps
Pr5.31*
Name
RS485 slave axis address
Mode
P
S
T
Range
0~127
Unit
—
Default
1
Data Type
16bit
Access
R/W
Address
053FH
Repower
-
During communication with the host (e.g. PC) to control multiple shafts, the shaft
being accessed by the host should be identified.
Note:
when using RS232/RS485, the maximum valid value is 31.
A.2.2 RS232/RS485 Communication Port
Port
Pin
Signal
CN4
CN5
1
,
9
RDO+(RS485)
2
,
10
RDO-(RS485)
3
,
11
/
4
,
12
TXD(RS232)
5
,
13
RXD(RS232)
6
,
14
VCC5V
7
,
15
GND
8
,
16
/
PE
A.3 Modbus Protocol
The driver supports 16bit data read and write of Modbus-RTU protocol, and its function codes include
0x03,0x06 and 0x10. 0x03 read data function code, 0x06 write single data function code and 0x10 write
multiple data function code.
Notes
:
1word=2byte=16bit