User manual of ELP AC Servo
www.leadshine.com
51
Data Type
16bit
Access
R/W
Address
022DH
Repower
o
Set up the time constant of the1st
delay filter in response to the positional
command.
When a square wave command for the target speed Vc is applied ,set up the time
constant of the 1
st
delay filter as shown in the figure below
Pr2.23
Name
positional command FIR filter
Mode
P
Range
0~10000
Unit
0.1ms
Default
0
Data Type
16bit
Access
R/W
Address
022FH
Repower
o
Set up the time constant of the1st
delay filter in response to the positional command.
When a square wave command for the target speed Vc is applied , set up the Vc
arrival time as shown in the figure below.
5.2.4
【
Class 3
】
Velocity/ Torque Control
Pr3.00
Name
Speed setup, Internal /External
switching
Mode
S
Range
0~3
Unit
—
Default
0
Data Type
16bit
Access
R/W
Address
0301H
Repower
-