13
2. SPECIFICATIONS
deg
Displays the hue in degrees.
d
Displays the distance from the center as a percentage
2.3.14
CINEZONE Display
CINEZONE Display
Function
Adds colors to the display in accordance with luminance
levels
Color
Linear (1024 colors), step (12 colors)
Upper Limit
-6.3 to 109.4% (values equal to or greater than the upper
limit are displayed in white)
Lower Limit
-7.3 to 108.4% (values less than the lower limit are
displayed in black)
Level Search Display
Function
Displays the specified luminance level range with
different gradations of colors
Luminance Level
-7.3 to 109.4%
Luminance Level Range Setting...................................................................... 0.5 to
100.0% (values greater than or equal to the specified
range are displayed in white; values less than or equal to
the range are displayed in black)
2.3.15
Audio Levels
Level Meter Display
Bar Display, Numeric Display
Displayed Channels
8ch
Meters
60 dB peak level, 90 dB peak level, average response
Reference Level
-20dB, -18dB, -12dB, -9dB
Scale
dBFS with the reference level set to 0 dB
Peak Hold Time
Channel
0.5 to 5.0 s, HOLD (when displaying the peak level)
Group Selection
Any two groups from groups 1, 2, 3, and 4
2.3.16
Status Display
SDI Signal Error Detection
Signal Detection
Detects the presence of an SDI signal
Format (Unknown)
Checks whether the signal matches an unsupported SDI
format or a format set manually
TRS Error
Detects TRS position and protection bit errors
Line Number Error
Detects 3G/HD signal line number errors
CRC Error
Detects 3G/HD signal transmission errors
EDH Error
Detects SD signal transmission errors
Gamut Error
Detects gamut errors
Detection Range Upper Limit 90.8 to 109.4%
Detection Range Lower Limit -7.2 to 6.1%
Filter
1 MHz LPF,2.8MHz LPF (HD only)
(removes transient errors; can be turned on and off)
Composite Gamut Error
Detects level errors that occur when component signals