Configuration with the PC
Logic
76/ 148
V 1.2
zirkon Configuration Manual
DEL:
(2)
The DEL function (delay) delays the input signal (In) by
the time under Delay Time (1/10 sec.). Control output is
Out.
This delay can prove vital when controlling recording
machines: as many devices expect a record signal first
and afterwards a delayed Play or Pause command for the
actual start of the recording.
IMP:
(4)
The function IMP (Impulse) turns an input signal (In) into
six different output signals.
The output Switch On Out becomes logical “one” if a
rising edge is supplied to the input. The status remains
until the time given under Pulsetime On (1/10 sec.) has
run out.
The signal Switch Off Out is set for a falling edge, for the
time given under Pulsetime Off (also 1/10 sec).
Switch On Off Out is set by both the rising and the falling
edge of the input signal, each according to the respective
time.
The outputs NEG Switch On Out, NEG Switch Off Out and
NEG Switch On Off Out are the same signals as described
above, only that they are negatived.