![Lawo AG zirkon Configuration Manual Download Page 15](http://html2.mh-extra.com/html/lawo-ag/zirkon/zirkon_configuration-manual_3955881015.webp)
zirkon system: introduction
System block diagramme
zirkon Configuration Manual
V 1.2
15/ 148
System block diagramme
The block diagramme shows a simple zirkon system with
system unit, central module and three channel modules.
The service PC allows an easy configuration but is not
needed for operating the console.
Connecting the system unit with the control panel and the
control modules among each other (CAN bus) requires
standard network cables (STP-CAT5 cable
s
hielded
t
wisted
p
air, with RJ 45 connectors on both sides and
one 1-to-1 assignment).
The maximum distance of the bus system is:
Please note that all system components are on the same
grounding potential.
The zirkon master board is fitted with an Ethernet
interface. For connecting a PC directly you need a
crosscable (CAT 5 STP RJ 45 connectors on both sides).
When the system is connected to a network via hub, like
with a CAN bus link, a 1-to-1 cable is necessary.
Transfer speed
500 kbit/sec
60 m
100 kbit/sec
300 m
10 kbit/sec
1000 m