Commissioning
Air conditioning and grounding of the zirkon
18/ 148
V 1.2
zirkon Configuration Manual
The PSU has the following features:
•
Input: 100-240 V / 50–60 Hz / max. 700 mA
•
Output: 12 VDC / 2,5 A
For country-specific plug norms we offer different
adapters.
Each casing of the operating modules is fitted with a
ground bolt.
1.
Fasten the grounding cable at the ground bolt
2.
Connect all operating modules with the grounding
cable.
3.
Establish a direct connection with the system unit
(parallel with the CAT-5 cable).
Attention!
Please see that the operating modules are on the same
ground potential like the system unit!
System unit
Each system-unit is delivered with a power supply unit
(PSU) as a standard. The PSU in a 3RU-frame has the
following characteristics:
•
Input: 100 240 VAC (PFC)/ 50–60 Hz/ max. 1,6 A
•
Output: 12 VDC / 8,3 A
The PSU in the 6RU mounting frame has the following
features:
•
Input: 100 240 VAC (PFC)/ 50–60 Hz/ max. 2A
•
Output: 12 VDC / 11 A
Tip