Lantronix
SM12XPA Web User Guide
33848 Rev. A
Page
67
of
473
Port Status
This page provides Link OAM configuration operational status. The displayed fields show the active configuration
status for the selected port.
Figure 3-6.4: Detailed Link OAM Status for Port 1
Parameter descriptions
:
PDU Permission
: This field is available only for the Local DTE. It displays the current permission rules set for the
local DTE. Possible values are "Link fault", "Receive only", "Information exchange only" and "ANY".
Discovery State
: Displays the current state of the discovery process. Possible states are Fault state, Active state,
Passive state, SEND_LOCAL_REMOTE_STATE, SEND_LOCAL_REMOTE_OK_STATE, SEND_ANY_STATE.
Peer MAC Address
: The MAC address of the peer device.
Mode
: The Mode in which Link OAM is operating, Active or Passive.
Unidirectional Operation Support
: This feature is not available to be configured by the user. The status of this
parameter is retrieved from the PHY.
Remote Loopback Support
: If status is enabled, the DTE is capable of OAM remote loopback mode.
Link Monitoring Support
: If status is enabled, the DTE supports interpreting Link Events.
MIB Retrieval Support
: If status is enabled, the DTE supports sending Variable Response OAMPDUs.
MTU Size
: It represents the largest OAMPDU, in octets, supported by the DTE. This value is compared to the
remotes Maximum PDU Size and the smaller of the two is used.