PAGE 46
NOTE: +12-17Vdc must be confirmed across the black and green wires at the upper
connector on the wire harness to perform this procedure.
Tools Required:
•
Phillips Head Screwdriver
•
Digital Multimeter
•
Jumper wire (only if your multimeter doesn’t have a continuity setting)
•
Towel or bubble wrap.
Instructions:
1.
Pull the console forward of the Velcro seal and then disconnect the membrane ribbon
cable.
2.
Remove all the display board screws holding the upper board to the membrane.
3.
Pop the upper display board off the membrane panel but leave the wire harness
connected to the upper board.
4.
Lay your towel or bubble wrap inside the control panel frame and lay the upper board
face up.
5.
Set your voltmeter to continuity and touch your two test leads together to make sure they
beep. Then proceed to follow the steps below to jump out the START & GND pins
which upper board application you’re working on.
FOR ET UPPER BOARDS:
FOR CT UPPER BOARDS:
FOR PT UPPER BOARDS:
Once you lay the upper board on a towel the START button is already on it. Just press it
manually and if it doesn’t turn on the upper board is bad. If it does then it’s a mounting
issue.
ELLIPTICAL PT/CT/ET MEMBRANE BYPASS TEST
View of upper
board when
face
up
Jump the two end
pins
View of upper
board when
face
up
Jump out these
pins