6.1 Main control box installation
The control box houses all the electrical control boards for the drive unit(s). It is located remotely from the drive
up to a maximum of 10m.
The location should be chosen with consideration to accessibility for adjustment and maintenance, where
possible it should be located in sight of the drive.
The box is surface mounted using suitable fixings. For a single and double drive installation the control box
measures 430mm high x 110mm width x 120mm depth for a single operator and 550mm x 110mm x 120mm for
a double operator system.
6.2 Floor unit - Drive housing installation
The cut out/excavation required for the floor box at a minimum is: 150mm(W) x 560mm(L) x 140mm(D). The
position of the drive depends on the variation of pivot used for hanging the door leaves (single/double action straps
or roller guide).
The floor unit is provided with a
‘mounting cradle’ that must be correctly installed and positioned before the motor
unit is applied.
Mounting cradle
Dimensions
– 525mm long x 135mm wide x 120mm high
The mounting cradle has been designed to offer the floor unit a secure fixing before concrete is applied to maintain
the IP rating of the operator.
The cradle is U-shaped with two positioning slots, four fixed fixing holes and a pivot point hole on the base, and
four slots to ensure exact location of the motor casing (two on each side).