FUNCTION STATUS
DESCRIPTION
*' SLAVE
OFF
Active function if
F01 = OFF
. Operation mode for the manual built-in selector in position
II
II
= Night Lock program
F07
Active function if
F01 = OFF
. Operation mode for the manual built-in selector in position
II
ON
II
= Open Door program
OFF
For operators with battery = in case of power failure the door keep on working normally with battery power
supply
F08
For operators with battery = in case of power failure the door opens and remains open in Automatic Door
ON
program
OFF
Battery monitoring = in case of empty or damaged battery the control unit buzzer beeps prior to ten
following opening cycles
F09
Battery monitoring = in case of empty or damaged battery the door opens and remains open in Automatic
ON
Door program
OFF
For operators with battery = in case of power failure or with almost empty battery the door keep on
working normally
F10
For operators with battery = in case of power failure or with almost empty battery the door opens and
ON
remains open
OFF
Selecting the program "Night Lock" the door remains closed and can be opened just with the
OPEN input
F11
Selecting the program "Night Lock" the door opens and remains open for 10" before closing in order to
ON
grant escape from building
OFF
Function for disabled persons deactivated
F12
Function for disabled persons activated; see paragraph "Courtesy function for disabled persons" for detailed
ON
information on this function mode
OFF
Function mode with automatic closure
F13
Step by step function: one Start or one OPEN input activates door opening while a second input is
ON
needed for door closure
OFF
Standard function mode on inputs internal and external radar
F14
ON
Step by step function mode with separate commands. The external radar input activates door opening,
whereas the internal radar input activates door closure. The command input (Start, OPEN and SPYCO
remote control) operate in standard mode
OFF
For double leaf door application: partial opening deactivated if key switch selector EV-MSEL is
connected
F15
ON
For double leaf door application: partial opening activated on Master leaf if key switch selector
EV-MSEL is connected
(active function if
F01=OFF
). For further details please check paragraph "Pedestrian
opening"
OFF
Active function if
F15=ON
. Partial opening on Master leaf active with key switch selector EV-MSEL in
program "Free manual door"
F16
Active function if
F15=ON
. Partial opening on Master leaf active with key switch selector EV-MSEL in
ON
program "Night Lock"
F17
This feauture is not applicable for the VISTA SMP operator
S
OFF
Closure safety sensor input deactivated; if a closure safety sensor is not installed
F18
S
ON
Closure safety sensor input activated; if a closure safety sensor is installed
28
Summary of Contents for Vista SMP