background image

 
 
9) 

ELECTRIC CONNECTIONS 

– (see 12. L-NEP Logic Board for connections between floor box and control board) 

 
 
 

PWN-T 

 

 

MAINS POWER SUPPLY 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECTOR 

 

 

 

 

 

 

 

   

 

230Vac 

 

 

 

 

 

 

M1 

 

 

MANUAL 

 

 

 

 

 

 

 

 

 

GND 

 

 

 

 

 

 

 

 

 

PROGRAM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL 

SELECTOR 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

PHASE 

SAFETY SENSOR FOR CLOSING 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

+24V- 

TEST 

 

 

 

 

 

   

M2 

 

 

 

 

 

 

 

 

 

 

AUX1 

SAFETY SENSOR FOR OPENING 

 

 

 

 

 

 

SEN./CL. 

 

 

 

 

 

 

 

 

TEST 

 

 

 

 

   

COMMON  

 

+24V- 

 

 

 

M6 

 

AUX2 

 

 

 

 

 

 

 

SEN./OP. 

 

 

 

 

 

 

25 TEST 

 

 

 

 

 

 

OPEN 

 

 

 

 

 

 

26  GND 

 

 

 

 

 

 

COMMON  

 

 

 

 

 

 

27 AUX3 

 

 

 

 

 

 

RAD.EX 

 

 

 

 

 

 

28  24V 

 

 

 

 

 

 

RAD.IN 

 

 

 

 

 

 

29  O.C. 

 

 

 

 

 

 

START 

10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3 

COMMON  

11 

OPEN 

 

 

 

 

 

 

 

- GND 

 

 

 

M7 

 

 

M8 

 

12 

 

 

 

 

 

 

 

 

 

 

 

13 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 

 

 

 

24V

 

N.O.  N.C.  +EL. 

+13V 

EXTERNAL RADAR 

INTERNAL RADAR 

 

15 

 

 

 

16  17  18 

19  20 

21 

M4 

+24V- 

 

+24V- 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

START 

 

 

 

 

 

 

 

 

ELECTRIC LOCK 

BUTTON 

 

 

 

 

 

 

 

 

24V 

 

 

 

 

 

 

 

 

 

   

 

DIGITAL 

 

 

 

 

 

 

 

 

 

PROGRAMMER N-DSEL 
 
 
 
 
 

 

14 

 

 

 

Summary of Contents for Vista SMP

Page 1: ...AUTOMATIC UNDERFLOOR SWING DOOR DRIVE Vista SMP Drive Unit Operator for automatic swing doors English Translation of the ORIGINAL INSTRUCTIONS VISTA SMP 16005_GB_Rel 2 2_09 2016 CD0420GB ...

Page 2: ... DRAWINGS 8 5 1 POSITION OF THE OPERATOR USING 76MM GLASS RAIL WITH DOUBLE ACTION ACCESSORIES 8 6 SITE PREPARATION 9 6 1 Main Control box installation 10 6 2 Floor unit drive housing cradle installation 10 6 3 Cut out prep mounting cradle install steps 11 7 POWER SUPPLY 12 8 CONTAIMENT 12 8 1 Example containment double door 12 8 2 Example containment single door 13 8 3 Control panel to floor opera...

Page 3: ...HOW TO CHANGE THE PRIMARY PASSWORD 36 19 3 HOW TO CHANGE THE SERVICE PASSWORD 37 19 4 ENABLING USER primary and service PASSWORD USAGE 38 19 5 DEACTIVAING THE USER PASSWORD USAGE 38 20 INFORMATION AND EVENTS MEMORY 39 21 MAINTENANCE 42 22 ELECTRIC LOCK APPLICATION 42 22 1 ELECTRIC LOCK ELECTRIC STRIKE 42 22 2 MAGNETIC LOCK 43 23 SAFETY SENSOR DEVICES 43 23 1 SENSOR OA EDGE T 43 23 2 SENSOR 4SAFE O...

Page 4: ...pheres or in the presence of flammable gases or fumes Make sure that the characteristics of the electric distribution network are compatible with the technical data indicated in this manual and that upstream of the system there is a double pole isolation switch with an opening distance of the contacts of at least 3mm and a 30mA residual current device Ensure the electric circuit is fully earthed T...

Page 5: ...fers to a typical installation but the data can be influenced by variables present in every system such as friction environmental conditions alignment of the leaf hinge etc 2 TECHNICAL SPECIFICATIONS POWER SUPPLY 115 230Vac 10 50 60Hz POWER 120W POWER SUPPLY OF EXTERNAL ACCESSORIES 24Vdc 1A ELECTRIC MOTOR 24Vdc FLOOR UNIT 525 x 135 x 130 mm WEIGHT 15 Kg floor box control panel PROTECTION DEGREE IP...

Page 6: ...NICAL SECTION 3 COMPONENTS OF THE VISTA SMP OPERATOR Floor unit Cradle 525mm long x 135mm wide x 135mm high Control panel Single 430mm long x 110mm wide x 120mm deep Double 550mm long x 110mm x 120mm deep 6 ...

Page 7: ...vots must be suitable and in a good condition The dimensions and weight of the leaf must lie within the operating limits of the operator max recommended 2 45m2 150KG The leaf must move in a regular manner without friction along its entire stroke The door requires mechanical end stops consisting of a mechanical retainer in the opening position and a final stopper when closed The door stop for the o...

Page 8: ...135 Standard Dorma bottom rail insert to recieve bottom pivot Vista Underfloor Operator 75 24 33 42 32 12 Elevation Section Vista Underfloor Operator 12 FFL Standard Dorma bottom rail insert to recieve bottom pivot Standard Dorma 100mm bottom rail 2 10 130 135 100 8 ...

Page 9: ...e early stages of installation can be costly in terms of time and money IF IN DOUBT ASK Caution To prevent damage to the drive It is essential to fit door stops for the door in both open and closed positions These can be fitted just prior to hanging door leaves but provision in terms of location and suitable choice should be considered in advance barrier with built in stop in open areas The drive ...

Page 10: ... housing installation The cut out excavation required for the floor box at a minimum is 150mm W x 560mm L x 140mm D The position of the drive depends on the variation of pivot used for hanging the door leaves single double action straps or roller guide The floor unit is provided with a mounting cradle that must be correctly installed and positioned before the motor unit is applied Mounting cradle ...

Page 11: ...to be determined by installer to offer secure fixing Remove the screw from the slotted holes Step 5 Place the motor unit into the cradle locating the threads into the slots on the side of the cradle Step 6 Secure motor unit into place by tightening nuts on threads Step 7 Make good by filling in void around floor units with concrete cement Cement box end view Floor cut out Cut out mounting cradle M...

Page 12: ...s Fire Alarm interface Door mounted safety sensors Where an interface to the fire alarm is required the signal cabling from the fire alarm system must be brought to the control box location The fire alarm contact should be a normally open volt free contact 8 1 Example of containment pair of doors Isee underfloor operator Control panel Safety sensor transfer loop cable 8 x 0 75mm 3 position switch ...

Page 13: ...bles into the unit Any water ingress may damage the unit appropriate materials and measures must be considered and taken For any uncertainty regarding recommended conduits contact www adaptaflex com 8 3 Control panel to floor operator wiring As standard there are two cables that are required as standard that must be run inside the 20mm conduit from the control panel to each floor drive 1 Motor cab...

Page 14: ...PHASE SAFETY SENSOR FOR CLOSING 24V TEST M2 AUX1 1 SAFETY SENSOR FOR OPENING SEN CL 2 TEST COMMON 3 24V M6 AUX2 4 SEN OP 5 25 TEST OPEN 6 26 GND COMMON 7 27 AUX3 RAD EX 8 28 24V RAD IN 9 29 O C START 10 M3 COMMON 11 OPEN GND M7 M8 12 A 13 B 14 24V C N O N C EL 13V EXTERNAL RADAR INTERNAL RADAR 15 16 17 18 19 20 21 M4 24V 24V START ELECTRIC LOCK BUTTON 24V DIGITAL PROGRAMMER N DSEL 14 ...

Page 15: ...t the motor and encoder cable in the floor operator box remove the stainless steel cover remove the primary steel cover lift back the black neopreme seal and you will find both cables ready for connection 9 Once connected carefully replace neopreme seal fix primary steel cover into place fix stainless steel cover plate into place 10 Mount door onto floor operator and top pivot and ensure the door ...

Page 16: ...LECTOR located on operator side panel factory wiring closed contact on position I to terminal 1 AUX1 Central contact to terminal 3 common Closed contact on position II to terminal 4 AUX2 For more information on the operating modes of manual program selector refer to Program selectors paragraph Terminals 2 3 Input of SAFETY SENSOR FOR CLOSING N C contact The operation of safety sensor for closing m...

Page 17: ...8 29 Open Collector output of door status it activates with open door and deactivates with closed door Connect a max 100mA charge between 29 O C and 28 positive 24V terminals In Interlock function F26 ON terminal 29 is used for connection of interlock operation for more information refer to Interlock system paragraph TERMINAL BOARD M7 Terminals 16 negative 17 positive 24Vdc output max 20W for the ...

Page 18: ...W1 dip switch for operator type selection 1 OFF 2 OFF single leaf operator or Master operator in double leaf 1 ON 2 OFF Slave operator in double leaf 13 N DSEL DIGITAL PROGRAMMER SCOPE AND CONNECTIONS N DSEL digital programmer is a tool necessary to the installer to configure the operation of the automatic door and perform the set up of operations functions and parameters to perform system diagnos...

Page 19: ...4 2 if digital programmer has already been used before 14 1 FIRST START OF N DSEL DIGITAL PROGRAMMER Power the VISTA SMP operator by mains voltage the control unit buzzer emits some quick short beeps Language selection is shown on the display of N DSEL digital programmer use F2 and buttons to move the arrow in correspondence with the language desired Press EXIT button to exit Language section and ...

Page 20: ...uration if the password typed is wrong you return to general programming menu It is recommended to change the default technical password Refer to Password management paragraph In this section F1 F3 buttons allows selecting the function ON OFF status while button allows moving to the following function Press F2 button to return to previous function Select the door type single leaf OFF or double lea...

Page 21: ... For more information refer to Safety sensors paragraph If S07 and or S08 functions are set to ON only Select test logic status used by operator control unit to monitor safety sensors The set up depends on the characteristics of sensor installed Select OFF when using 4SAFE ON SW or OA EDGET type sensors select ON when using TOP SCAN S type sensors For more information refer to Safety sensors parag...

Page 22: ...he leaf exceeds the limits allowed or installation levels shown on technical installation drawings are not met or frictions exist on the fixture in this case the movements of automatic door are difficult and the opening closing cycle could not be completed Impact safety ensure that stop and reverse of moving direction are performed if the leaf movement is hindered To set up the available functions...

Page 23: ...ction OFF default preset Disconnect manual selector wires from terminal board of PWN T module if EV MSEL mechanical selector is installed ELECTRIC CONNECTIONS Terminal 1 of EV MSEL to terminal 9 Internal radar of VISTA SMP panel PWN T Terminal 2 of EV MSEL to terminal 3 Common of VISTA SMP panel PWN T Terminal 3 of EV MSEL to terminal 1 AUX 1 of VISTA SMP panel PWN T Terminal 4 of EV MSEL to termi...

Page 24: ...xternal radar input Single direction automatic program input only To exclude the outgoing detection on internal radar input Open door program The door stops in complete opening position Night lock program The door can only be open by OPEN input or radio control if EN RF1 radio receiver is installed Free manual door The automatic operation is disabled and door can be manually open Power warning lig...

Page 25: ...by step operation Symbol F2 on display goes off F1 Door opening command Press F1 button to open the door but only in bi directional and single direction programs if F33 function OFF Press F1 button to open the door in all operating programs both automatic and night lock if F33 function ON F3 It is only used in one MASTER SLAVE double leaf door automated device F3 button has no function on the main...

Page 26: ... button To exit the general programming menu and return to the operating program view press EXIT button DIAGRAM 1 5 EXIT EXIT EXIT EXIT F1 F1 F1 F1 ENTER ENTER UNUSED ENTER INITIAL SET UP FUNCTIONS AND REGULATIONS LANGUAGE SECTION SECTION SECTION EXIT EXIT EXIT EXIT F1 F1 F1 ENTER ENTER UNUSED ENTER SERIAL PASSWORD MAINTENANCE COMMUNICATION MANAGEMENT SECTION SET UP SECTION SECTION Refer to par 14...

Page 27: ... the following function push button allows returning to the previous function Here the explanation of each single function FUNCTION STATUS DESCRIPTION SLAVE OFF Choosing the program selector manual built in selector or mechanical key switch EV MSEL F01 ON Choosing the program selector digital selector N DSEL OFF Singe leaf door just on display repeat initial set up in order to change it F02 ON Dou...

Page 28: ...ns deactivated F12 Function for disabled persons activated see paragraph Courtesy function for disabled persons for detailed ON information on this function mode OFF Function mode with automatic closure F13 Step by step function one Start or one OPEN input activates door opening while a second input is ON needed for door closure OFF Standard function mode on inputs internal and external radar F14 ...

Page 29: ... paragraph Safety Sensors Device F23 Function disabled F24 OFF OPEN input is not enabled in the Free manual door work program ON OPEN input is enabled also in the Free manual door work program in order to allow the automatic opening of the door OFF Constant pause time F25 Automatic pause time increases if door is not closing properly due to the high flow of persons walking ON through it OFF Interl...

Page 30: ...he reached motor power limit please check paragraph Functional Testing F34 S ON Deactivates buzzer warning relative to the reached motor power limit F35 Function disabled F36 Function disabled F37 Function disabled F38 Function disabled F39 Function disabled OFF Cyclic function disabled F40 Cyclic function Activates the continuous door opening and closing cycle this function is meant to be used fo...

Page 31: ...from this potentiometer If P03 0 the door stop ever increasing the value the door use low speed to approach the end of the opening At maximum value the area start from about 45 from the end of opening P04 Thrust power during opening Increase this value for higher motor thrust power S during opening and closing if set closing by motor cycle P05 Pause time can be regulated between 0 and 60 seconds I...

Page 32: ...ercoming any friction and achieving complete door closure At value 100 time would be 1 5 Motor thrust during end opening The defaul value 12 is low in order to reduce P17 leaf juddering during end opening phase This parameter value has to be increased in S case of any difficulty in the last door opening phase and thus increasing motor thrust power P18 Distance between leaf physical end stop and op...

Page 33: ... hand S At default value 00 the function is disabled and the door does not close after an opening by hand Setting the value 01 the door closes with minimum force Increase the value for higher force during reclosing P31 Parameter disabled P32 Parameter disabled This parameter allows you to select the number of cycles of opening closing after which the display of the program selector N DSEL show the...

Page 34: ...stance controlled by P13 parameter C Adjusting area of approach speed A C Closing time B FIG 3 A A Adjusting area of Push Go controlled by P08 parameter before automatic opening B Adjusting area of Push Close controlled by P22 parameter before automatic closing FIG 4 A FIG 5 A B A Area from where if safety sensor in A Intervention area of Wind Stop with opening detect an obstacle the door opens op...

Page 35: ...sword and be very careful not to forget it b PRIMARY PASSWORD for the system s owner user It is a 5 character password used by the user to prevent unauthorized persons from having access to N DSEL programmer and change the work program Using a primary password is optional and must be enabled by system s owner Default preset primary password is A A A A A WARNING When enabling the password be very c...

Page 36: ...tial set up functions and adjustments settings of serial communication and maintenance section the new password stored needs to be typed The password is not required afterwards when toggling among sections without exiting the general programming menu If the password typed is not correct PASSWORD ERROR is shown on display and the general programming menu is restored 19 2 HOW TO CHANGE THE PRIMARY P...

Page 37: ...ain 19 3 HOW TO CHANGE THE SERVICE PASSWORD Select SERVICE PASSWORD Press OK F1 button Type the primary password Type the new service password selecting a combination of 5 characters from the letters A B C D It is required to repeat the new password so type the previous combination again If the password typed is correct PASSWORD OK is shown on display for one second thus reverting to PASSWORD MANA...

Page 38: ... the automatic door work program the primary or service password must be typed When the user decides to enable the password usage it is recommended to change the combination of both primary and service password 19 5 DEACTIVATING THE USER PASSWORD USAGE From PASSWORD MANAGEMENT section type PASSWORD ON OFF Press OK F1 button Type the primary password Press OFF F1 button to disable user password usa...

Page 39: ...lows shifting from M to S and vice versa In case of single leaf automation letter M is shown on the top right side of display F1 button allows shifting to events memory to display error messages and return to information area by pressing it again EXIT button allows returning to main view of door work program DIAGRAM 2 I1 I2 INFORMATION AREA E1 E2 MEMORY EVENTS 5 I1 F2 F2 F2 F2 F2 I2 I3 I4 I5 I6 F1...

Page 40: ...o B Display Micro B software release of logic board L NEP I6 Identificative number Identification number containing useful data for manufacturer The events memory stores the last 5 error messages in chronological order When all the 5 memory cells are full of messages the following event stored shall be located in E1 cell the other memory events are shifted by one position and the event in E5 cell ...

Page 41: ...ncoder signals are not detected or the motor does not turn Fault detected during the test operation of the encoder The test on the safety opening sensor is failed The test on the safety closing sensor is failed Control the smoothness of the door and that there are no obstacles along the way that motor and encoder are connected and try again to set up the door Check that the cables and connector of...

Page 42: ...o Master operator or S if Slave operator is involved Every touch on F3 button allows shifting from M to S and vice versa In case of single leaf automation letter M is shown on the top right side of display 22 ELECTRIC LOCK APPLICATION To block the door in closing position Neptis SMP operator is ready to drive an electric strike an electric lock or an magnetic lock 22 1 ELECTRIC LOCK ELECTRIC STRIK...

Page 43: ...ING CONNECTION SENSOR OA EDGE T WIRING CONNECTION NEPTIS SMP OPERATOR Wiring between the sensor and the terminal block of the PWN T board on VISTA SMP operator 1 WHITE Supply power TERMINAL 17 2 BROWN Supply power TERMINAL 16 3 GREEN COM Closing side TERMINAL 3 COM 4 YELLOW N C Closing side TERMINAL 2 Safety sensor in closing 5 GREY N O Closing side do not connect 6 PINK COM Opening side TERMINAL ...

Page 44: ...g between the sensor and the terminal block of the PWN T board on VISTA SMP operator 1 Supply power TERMINAL 16 2 Supply power TERMINAL 17 3 COM TERMINAL 7 COM 4 N O do not connect 5 N C se il sensore è installato dal lato apertura TERMINAL 5 Safety sensor in opening 5 N C se il sensore è installato dal lato chiusura TERMINAL 2 Safety sensor in closing 6 TEST test input TERMINAL 25 TEST SETTING ON...

Page 45: ... reached the L1 led will blink slowly for 5 times d Once the transmitter saving procedure is finished exit the programming mode by pressing and holding the SW1 button until the L1 led turns off O 4 USE OF THE RADIO CONTROL By pressing the button of a saved SPYCO transmitter the automatic door opens and the L1 LED of the receiver will remain on until the button of the transmitter is released The ra...

Page 46: ...F1 can be used as disable people input Adjust the pause time parameter P05 on the digital programmer N DSEL to hold the door open for a sufficient time to allow the disabled person to be able to pass through the door before the automatic closing If at the end of the opening cycle or during the pause time the safety sensor in closing detects the presence of the disabled people the pause time is red...

Page 47: ... the program switch and the electric lock must be connected to the Master operator Safety sensors installed on the master leaf must be connected to the operator Master safety sensors installed on the slave leaf must be connected to the Slave operator If the door has a double electric lock to lock each door individually connect the electric lock that blocking the slave door at the slave operator Ma...

Page 48: ...and S fig C and the programmer N DSEL will be able to manageboth master and slave operators fig A fig B fig C Press EXIT SET push button to exit from Serial communication setting and come back to the general programming menu 4 INITIAL SET UP From the general programming menu enter in the INITIAL SET UP section as indicated in par 16 Enter the 10 digits of the technique password to access the confi...

Page 49: ...guration of the contact on the OPEN input between terminals 6 7 of the PWN T board Select ON with normally open contact or if you do not useOPEN INPUT Select OFF if you are using a device with a normally closed contact The operators are now ready to start the set up cycle Press the button OK to start the set up cycle 6 INITIAL SET UP CYCLE The Master operator starts opening at slow speed after 4 b...

Page 50: ...mits or that the installation dimensions given in the drawings of installation have not been met or that are present to much friction on the frame in which case the automatic door has difficulty moving and may fail to complete the cycle of opening and Safety in case of impact verify that opposing an obstacle to the movement of a door the operator stop and reverse the direction of travel of both do...

Page 51: ...ons it s related to the Master if display show letter S operation performed it s related to the slave operator c INFO AREA AND MEMORY EVENTS Also the information and the events can be accessed individually Once you enter in the information menu as described in par 20 press the F3 button to selected on which operator you want to display information and events At the top right of the display will sh...

Page 52: ...SWITCH ON OFF between the terminals 3 COMMON and 1 AUX1 on both PWN T it is possible to disable the Interlock function with the contact closed and to re enable the function with the contact open The use of this switch is optional it is used only to disable temporarily the interlock detection and to allow the free passage between the two doors To use Interlock functioning it s necessary to install ...

Page 53: ...of pause time The operation is the same coming from the opposite direction To open the door even when the other is open it is necessary to operate the command of OPEN input 27 3 INTERLOCK APPLICATION WITH ONLY ONE INTERNAL RADAR DOOR 1 DOOR 2 EXTERNAL INTERNAL RADAR RADAR START COMMON DETECTOR It s possible to use a single sensor that cover the common inside area to open the door Connected the sen...

Page 54: ...y sensor in opening failed 1 BIP medium before opening Battery faulty or low level 1 BIP before closing Test of the safety sensor in closing failed 1 BIP long 1 second Internal fault detection 29 MAINTENANCE PROGRAM To guarantee and to keep a secure functioning in door s lifetime it recommended make maintenance every 6 months The installer can set the number of cycles of opening closing after whic...

Page 55: ... that the operator NEPTIS SMP has been realized to be incorporated in a machine or to be assembled with other devices to constitute a machine covered by Machine Directive 2006 42 EC Label declares as well that the product cannot be operated until the final machine where the product is incorporated has been certified as compliant with the Machine Directive 2006 42 EC European Harmonized standards a...

Page 56: ...VISTA SMP Made in UK ...

Reviews: