The function S05 must be selected ON if a safety sensor in closing is installed.
Selecting this functionis valid for both Master and Slave operators.
The function S06 must be selected ON if a safety sensor in opening is installed.
Selecting this functionis valid for both Master and Slave operators.
·
The function S07 is displayed only if the function S05 = ON
Select ON if you have installed a safety sensor in closingmonitored (as required by standard
EN16005) to activate the testsensor at the beginning of each closing cycle.
For more information, refer to par. "Safety sensors devices".
Select OFF if the safety sensor in closing is notarranged to be monitored.
·
The function S08 is displayed only if the function S06 = ON
Select ON if you have installed a safety sensor in openingmonitored (as required by
standard EN16005) to activate the testsensor at the beginning of each opening cycle.
For more information, refer to par. "Safety sensor devices".
Select OFF if the safety sensor in opening is notarranged to be monitored.
·
The function S09 is displayed only if the function S07and/or S08 = ON.
Select the logical state of the test used to monitor the safety sensors.
The setting depends on the characteristics of the sensor.
Select OFF for sensors "4SAFE SW ON" or "OA-EDGE T.
Select ON for the sensor "TOP SCAN-S".
For more information, refer to par. "Safety sensor devices".
· Configuration of the contact on the OPEN input between terminals 6-7 of the PWN-T board.
Select ON with normally open contact, or if you do not useOPEN INPUT.
Select OFF if you are using a device with a normally closed contact.
· The operators are now ready to start the set-up cycle.
Press the
button (OK) to start the set-up cycle.
6. INITIAL SET-UP CYCLE
·
The Master operator starts opening at slow speed after 4 beeps of start signal. At the end of the opening cycle, a prolonged 3
seconds beep, will signal the end of the Master operator set-up. The Master operator leaf remains opened to permit the set-up of
the slave operator.
·
The Slave operator starts opening at slow speed after 4 beeps of start signal. At the end of the opening cycle, a prolonged 3
seconds beep, will signal the end of the Slave operator set-up.
·
The set-up is now completed, the closing cycle start automatically providing to close as first the slave operator and then after a
delay time the master operator.
Just for model SMT-B e SMT:
The set-up cycle of the operator without spring is fully operated by the motor, and so the function S02 must not take in to
account. The set-up steps for these operators are the following:
Slow opening of the Master operator and leaf hold in opening
position; Slow opening of the Slave operator ;
Slow closing of the Slave operator, prolonged 3 seconds beep at the end of the closing to signal the end of the Slave operator set-up.
Slow closing of the Master operator, prolonged 3 seconds beep at the end of the closing to signal the end of the Master operator set-up.
49
Summary of Contents for Vista SMP
Page 56: ...VISTA SMP Made in UK ...