PARAMETER
Ref. Drawing
DESCRIPTION
*'SLAVE
Closing stroke to release electric lock
(active if
F04=ON
). At 0% (default value) the
P10
function is disabled. Increase this value to adjust the closing stroke power of 0,5 second
S
closing before opening cycle. Used to easily release the electric lock.
P11
Opening delay at electric lock activation
(active if
F04=ON
). By 0% (default value)
S
the function is disabled. Increase this value to increase the delay leaf opening in respect
of the electric lock activation (4 seconds at 100%).
Slowing down distance in opening.
Slowing down distance in opening. Distance
P12
Fig.1
from where the leaf start the low speed in opening. Increase this value to adjust door
S
leaf slowing distance.
P13
Fig.2
Slowing down distance in closing.
Slowing down distance in closing. Distance from
S
where the leaf start the low speed in closing. Increase this value to adjust door leaf
slowing distance.
P14
This parameter is not applicable for the VISTA SMP operator
Motor thrust power in closing.
(active if
F17=OFF
for spring closing units). At 0%
P15
Fig.6
(default value) the function is disabled. Increase this value for higher motor thrust
S
power during closing phase. In swing closing units, this parameter is active only when
door closure is achieved with motor thrust.
P16
Motor thrust time during end closing.
Increase this value to adjust time during
S
which the motor thurst is active in the last closing phase, thus overcoming any friction
and achieving complete door closure. At value 100% time would be 1,5''.
Motor thrust during end opening.
The defaul value (12%) is low in order to reduce
P17
leaf juddering during end opening phase. This parameter value has to be increased in
S
case of any difficulty in the last door opening phase and thus increasing motor thrust
power.
P18
Distance between leaf physical end stop and opening end-running.
Increase
S
this value to increase the gap between the physical end stop on the floor and the
position of the leaf with the door full open. This setting can be adjusted for about 5°.
P19
Leaf opening delay.
For double leaf application. Increase this value to adjust opening
delay between Slave and Master unit. This setting is necessary in case of overlapping
leaves. At minimum value 0% both leaves start opening at the same time.
P20
Leaf closing dealy.
For double leaf application. Increase this value to adjust closing
delay between Master and Slave unit. This setting is necessary in case of overlapping
leaves. At minimum value 0% both leaves start closing at the same time.
Assisted closing virtual spring
P21
(This parameter is active only if parameter P30 is not set to 00).
S
Increasing this value increases the force when the door starts closing after a manual
push opening, in all those situations where the virtual spring power is not enough to
start the reclosing cycle.
P22
Fig.3
Push & close.
If steady door is manually pushed to close direction, an automatic
S
closure is activated. Increase this value to adjust closing corner needed for door leaf to
start automatic closing. Setting range between 2° and 15°.