FUNCTION STATUS
DESCRIPTION
*' SLAVE
OFF
Internal and external radars are deactivated during closing phase in "Night Lock" program
F32
Internal and external radars are activated during closing phase in "Night Lock" program, causing the door
ON
reopening
OFF
Push button
F1
of digital selector N-DSEL enables door opening only during automatic program modes
F33
Push button
F1
of digital selector N-DSEL enables door opening both during automatic program modes and
ON
during "Night Lock" program
OFF
Activates buzzer warning relative to the reached motor power limit (please check paragraph "Functional Testing")
F34
S
ON
Deactivates buzzer warning relative to the reached motor power limit
F35
Function disabled
F36
Function disabled
F37
Function disabled
F38
Function disabled
F39
Function disabled
OFF
Cyclic function disabled
F40
Cyclic function. Activates the continuous door opening and closing cycle; this function is meant to be used for
ON
function testing or laboratory purposes
*' For double leaf swing door application.
In the column Slave of the present spreadsheet, the functions marked with letter S, have to be
separately configured on Slave operator. All other functions not marked with letter S, have to be set on Master operator and are common
for both units.