PLM Series Operation Manual rev 1.1.3
11. Appendix
81
PLM 10000Q
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
120 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via NomadLink
4.8
0
4.8
16
4
Powered on, idling.
145
0
145
496
125
Amp (I)
Watt
Pink noise (1/8
rated power)
16 Ω / Ch.
660 x 4
9.3
4.8
687
330
357
1218
307
8 Ω / Ch.
1300 x 4
16.3
8.5
1250
650
600
2048
516
4 Ω / Ch.
2300 x 4
25.2
13.2
2014
1150
864
2949
743
2.67 Ω / Ch.
2700 x 4
31.3
16.4
2553
1350
1203
4106
1034
2 Ω / Ch.
2350 x 4
29.2
15.2
2341
1175
1166
3980
1003
Pink noise
(max power)
*3)
16 Ω / Ch.
660 x 4
14.7
7.7
1098
660
438
1495
377
8 Ω / Ch.
1300 x 4
26.0
13.6
2049
1300
749
2556
644
4 Ω / Ch.
2300 x 4
45.8
23.9
3746
2300
1446
4935
1243
2.67 Ω / Ch.
2700 x 4
52.5
27.4
4420
2700
1720
5870
1479
2 Ω / Ch.
2350 x 4
51,0
26.6
4179
2350
1829
6242
1573
20 kHz
Surveillance
tone
16 Ω / Ch.
1 x 4
2.7
1.4
160
4
156
532
134
16 Ω / Ch.
0.25 x 4
2.5
1.3
149
1
148
505
127
Mains connector - 230 V CE version / 230 V ETL version / 115 V ETL version
32 A, Neutrik
@
PowerCon
@
Twist lock
*1) The power output section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead,
measured and specifi ed here is what is known as the “Active Power” of the power output section providing useful, real-world values of power
consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are converted from 230 V fi gures.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation. Note
that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if
operation is
momentarily
in excess of max. ratings.
Lake is a registered trademark of Lab.gruppen AB. PLM and Powered Loudspeaker Management are trademarks of Lab.gruppen AB.
Dante is a trademark of Audinate Pty Ltd. All other trademarks are the property of their respective owners.
Copyright © 2007-2009 Lab.gruppen AB. All rights reserved.
Table 11.4b: PLM 10000Q Current Draw and Thermal Dissipation specifications