48
PLM Series Operation Manual rev 1.1.3
9. Front Panel Interface
9.11 Warning and Fault Indications
The following table gives indications for warning (yellow) and fault/clip/mute (red) conditions, listed sepa-
rately. Additional information in table 11.1.
Warning
LED
LED
Number
On Screen
Warning Text
Event Log Text
Power Channel Temp Warning
Channel
5~8
TEMP WARN:CH
Temp warning: Amp channel
Fewer Speakers
Channel
5~8
UNDER SPKR CNT
Under Speaker Count
More Speakers
Channel
5~8
OVER SPKR CNT
Over Speaker Count
Speaker Magnet Temp Warning Channel
5~8
TEMP WARN:MAG
Temp Warning: Speaker Magnet
Speaker VC Temp Warning
Channel
5~8
TEMP WARN:VC
Temp Warning: Speaker Voice-Coil
Uncertain About Load
Channel
5~8
TYPE: UNCERTAIN
Uncertain About Speaker Type
Load Not Verified
Channel
5~8
LOAD NOT VER
LoadSmart: Load not verified
SpeakerSafe Precision Low
Channel
5~8
LM PREC. LOW
SpeakerSafe: Precision Low
Controller/Frame Offline
Frame
1
CTRL OFFLINE
Frame Offline
SpeakerSafe Not Started
Channel
5~8
SPKSAFE INACT
SpeakerSafe Not Started
Table 9.11a: Yellow LED Warning Table
Fault/Clip/Mute
LED
LED
Number
On Screen
Warning Text
Event Log Text
No Input Source Available
Module
2, 3
n/a
Frame Fault: No Input Source
Internal Audio Interface Fault
Frame
1
AUDIO FAULT
Frame Fault: Audio Interface
Power Channel Temp Fault
Channel
5~8
TEMP FLT:CH
Temp Fault: Amp Channel
Speaker Magnet Temp Fault
Channel
5~8
TEMP FLT:MAG
Temp Fault: Speaker Magnet
Speaker VC Temp Fault
Channel
5~8
TEMP FLT:VC
Temp Fault: Speaker Voice Coil
Power Supply Unit Temp Fault
Frame
1
TEMP FLT:PSU
Temp Fault: Power Supply Unit
DSP area Temp Fault
Frame
1
TEMP FLT:DSP
Temp Fault: DSP Area
No Load Detected at Power Output
Channel
5~8
NO LOAD
Channel Fault: No Load Detected
Short Circuit Protection
Channel
5~8
SHORT CIRCUIT
Channel Fault: Short Circuit Protection
Very High Frequency Protection
Channel
5~8
VHF FAULT
Channel Fault: Very High Frequency
Power Channel Failure
Channel
5~8
SERVICE CH.
Channel Fault: Unit Needs Service
Wrong Type of Speaker
Channel
5~8
WRONG LOAD
Load Type / Routing Mismatch
PSU Fault / Undervoltage
Frame
1
PSU FAULT
Frame fault: PSU Undervoltage
Current Average Limiter
Channel
5~8
CAL ACTIVE
n/a
Physical Input Clip
Module
2,3
INPUT CLIP
n/a
Module Output Clip
Module
2,3
MOD. CLIP
n/a
Current Protection Limiter
Channel
5~8
CURRENT CLIP
n/a
Power Average Limiter
Frame
1
PAL ACTIVE
n/a
Voltage Clip Limiter
Channel
5~8
VOLTAGE CLIP
n/a
Module Input Mute
Module
2,3
MOD. IN MUTE
Module Input Mute
Module Output Mute
Channel
5~8
MOD. OUT MUTE
Module Output Mute
Amp CH Mute
Channel
5~8
AMP CH. MUTE
Amp Channel Mute
Analog Input Fault
Frame
1
ANALOG IN FAULT
Frame Fault: Analog input
Table 9.11b: Red LED Fault/Clip/Mute Table