PLM Series Operation Manual rev 1.1.3
9. Front Panel Interface
53
9.12.3 Meter View 3 – Temperature View
PSU
DSP
07%
13%
TEMP METERS
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
AMP
VC
MAG
04%
30°
30°
A
1
A
2
A
3
B
4
Figure 9.12.3: Temperature meter
view
Temperature View provides information about the current operating temperatures within the PLM and
loudspeakers.
Frame block:
Line 1
▸
TEMP METERS flag – confirms Temperature view
Line 2
▸
(blank)
Line 3
▸
Power supply temperature meter, denoted by ‘PSU’. A bargraph meter displays the current PSU
temperature as a percentage of its maximum permitted value. The numerical percentage value is also
displayed at the right-hand end of the meter.
Line 4
▸
Processor temperature meter, denoted by ‘DSP’. A bargraph meter displays the current tem-
perature of the main Lake processor as a percentage of its maximum permitted value. The numerical
percentage value is also displayed at the right-hand end of the meter.
Blocks 2, 3 and 4 are unused in Temperature View.
Output blocks:
Line 1
▸
Current actual temperature of the channel’s power output stage (denoted by ‘AMP’) as a
percentage of its maximum permitted value. The numerical percentage value is also displayed at the
right-hand end of the meter in dB relative to signal clip.
Line 2
▸
Computed temperature of voice coil of loudspeaker connected to the output channel (denoted
by ‘VC’). This parameter is calculated using the power currently being dissipated in the load and loud-
speaker data from the LoadLibrary Fingerprint as it is presented by the SpeakerSafe output. Displayed in
degrees Celsius. The numerical value is also displayed at the right-hand end of the meter.
Line 3
▸
Computed temperature of magnet of loudspeaker connected to the output channel (denoted by
‘MAG’). This parameter is calculated and displayed in a similar way to the voice coil temperature.