PLM Series Operation Manual rev 1.1.3
13. Technical Specifications
103
General
Number of input channels
2
Number of output channels
4
Peak total output all channels driven
10800 W
Max. Peak output voltage per channel
153 V
Max. output current per channel
49 A peak
Max. Output Power
2 ohms
4 ohms
8 ohms
16 ohms
All channels driven
2350 W
2300 W
1300 W
660 W
Channels A and B, while channels C and D are driven at -3 dB
2)
2350 W
2400 W
1300 W
660 W
All channels driven into optimal impedance interval
> 2700 W into 2.4 – 3.2 ohms
Audio Performance
THD + N 20 Hz - 20 kHz for 1 W
<0.05%
THD + N at 1 kHz and 1 dB below clipping
<0.04%
Dynamic range with digital inputs (for all supported sample rates)
>116 dB
Dynamic range with analog inputs
>114 dB
Frequency response (1 W into 8 ohms, 20 Hz - 20 kHz)
+ /-0.05 dB
Input Common Mode Rejection (CMR) 20 Hz to 1 khz
> 78 dB
Internal sample rate
96 k
Internal data path
32 bit fl oating point
Product propagation delay, best case (96 kHz AES)
1.61 ms
Product propagation delay, analog input
1.68 ms
Sample Rate Converters
THD + Noise
0.00003 %, 20 Hz - 20 kHz, unweighted
Analog to Digital inputs
THD + Noise
0.00022 %, typical at 1 kHz unweighted at +26 dBu headroom setting
0.00033 %, typical at 20 Hz and 20 kHz unweighted at +26 dBu headroom setting
AES / EBU inputs
Supported resolutions
≤ 24 bit
Supported sample rates
44.1, 48, 88.2, 96, 176.4, 192 kHz
Dante Audio Network
Supports redundant paths
Yes
Flexible topology
Yes
Network latency
0.8, 1.3 and 4 ms
Device presets
Local memory locations for the settings of the product
100
Limiters
Adjustable Inter-Sample Voltage Peak Limiter (ISVPL)
17.8 - 153 V, step size 0.1 V
Current Peak Limiter < 300 ms
49 A peak
Current Average Limiter (CAL) > 300 ms
25 Arms
LimiterMax (rms and peak limiters)
– MaxRMS (rms voltage limiter)
Yes
– MaxPeak (peak voltage limiter)
Yes
Gain
Amplifi er gain
22 - 44 dB, step size 0.1 dB
Analog attenuator
-Inf to 0 dB, step size 0.25 dB
Back panel interface
AES / EBU / I/O (input + link)
2 x 3-pin XLR
Analog, 2-channel I/O (input + link)
4 x 3-pin XLR, electronically balanced
Output connectors
Neutrik Speakon (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs) (must be specifi ed upon order)
Auto 10/100, Auto Uplink
2 x RJ45 EtherCon
Control and monitoring interface
Via Ethernet for Lake Controller software
Detachable mains cord
Neutrik PowerCon 32 A
Cooling
Two fans, front-to-rear airflow, temperature controlled speed
Front-panel user interface:
Display, daylight readable LCD
2.5 inch
Fault/Warning/Limit/Clip indicators
RGB LEDs
Mute and soft function buttons
8 provided
Standby Power button
On/Off
Mute Enable button
Enables muting of outputs and inputs via soft-button keypad
Meter button
Toggles through meter views
Menu button
Provides a menu driven interface for full function front panel control
Rotary Encoder
Yes
Exit button
Provides a “back” function
Power
Operating voltage, 230 V / 115 V nominal
1)
140-265 V / 70-135 V (45 - 66 Hz)
Soft start / Inrush Current Draw
Yes / max. 5 A
Mains Power Average Limiter (PAL)
Yes
Dimensions (W/H/D)
W: 483 mm (19”), H: 88 mm (2 U), Overall D: 470 mm (18.5”) deep including handles and rear support.
Weight
13.5 kg (30 lbs.)
Finish
Black painted steel chassis with black painted steel / aluminum front
Approvals
CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
Note 1)
: Separate 230 V or 115 V versions available. Not selectable on the product.
Note 2)
: Assymetrically loading the output channels (as shown, for example): If one channel has reduced output power requirements, the voltage drop from the power supply will be reduced,
resulting in a higher voltage and power output for the other channel.
All specifications are subject to change without notice.
Intercooler, Class TD and Lake are national and/or international registered trademarks of Lab.gruppen AB. PLM, Powered Loudspeaker Management, R.SMPS, LoadLibrary, LoadSmart,
SpeakerSafe and ISVPL are trademarks of Lab.gruppen AB. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. Contour, Mesa Quad EQ, Mesa Parametric EQ, Raised
Cosine Equalization, LimiterMax and Iso-Float are trademarks of Dolby Laboratories. Audinate is a registered trademark of Audinate Pty Ltd. Dante and Zen are trademarks of Audinate Pty Ltd.All
other trademarks remain the property of their respective owners.
Copyright © 2009 Lab.gruppen AB.
All rights reserved.
PLM 10000Q
These figures are accurate at the time of printing but please note that all figures are subject to change without
notice. For the most accurate and current information available, please visit www.labgruppen.com/plm