54
PLM Series Operation Manual rev 1.1.3
9. Front Panel Interface
9.12.4 Meter View 4 – Input View
RACK 3:3
OK
INPUT ROUTER 1
ANALOG 1 (26dBU)
||||||||||||||||||| -09
OK
INPUT ROUTER 2
ANALOG 2 (26dBU)
||||||||||||||||||| -09
OK
INPUT MIXER A
1: ON / 2: OFF
||||||||||||||||||| -04
OK
INPUT MIXER B
1: ON / 2: OFF
||||||||||||||||||| -04
OK
Ω
COMBINED CHANNEL
STATUS:
INPUT METERS
VOLTAGE CLIP
Figure 9.12.4: Input meter view
Input meter view provides further input signal information. This view enables inspection of the input signal in
a step before the input mixer and the HOME View input meters.
Frame block:
Line 1
▸
INPUT METERS flag – confirms Input view
Line 2
▸
Frame name – displays the frame name. Default is the PLM model name.
Line 3
▸
(blank)
Line 4
▸
Frame fault/warning – In the event of a Frame fault or warning, text describing the problem is
displayed here.
Input blocks:
Line 1
▸
Input router – displays which input router used.
Line 2
▸
Displays what type of input used for the specific input router. Analog inputs are displayed with
headroom selection and AES/EBU input is displayed with the current sample rate.
Line 3
▸
Input meter showing signal level at the input to the input router. A numeric indication in dB of
the difference between the signal level and input clip level is also provided at the right-hand end of the
meter.
Line 4
▸
Router fault/warning – In the event of a Router fault or warning, text describing the problem is
displayed here.
Button action
▸
Pressing the soft button serves as a shortcut to the specific input router. See section
9.13.3 for more information.
Block 4
Icon indicates AES/EBU Input termination state. An omega icon indicates input is terminated; no icon
▸
indicates input is unterminated.
Pressing this soft button serves as a shortcut to AES termination selection.
▸
Output blocks:
Line 1
▸
Input mixer name – displays the input mixer name.
Line 2
▸
Displays the input mixer configuration. This can be altered from the Lake Controller. Both 1 and
2 activated (on) indicates that the input to the Lake Processing Module is a mix of the signal from input
router 1 and input router 2.
Line 3
▸
Output meter showing signal level out from the input mixer to the Lake Processing Module. A