Relay (CA1aF-12V-N-5)
The relay (CA1aF-12V-N-5) is located in front
of the bottom right of the fuel tank.
This image is viewing up from the lower
section of the main vehicle.
This is the interlock system associated with
the seat, reel rotation ON, #4 mower
proximity, and #5 mower proximity switches,
and controls engine starting and reel cutter
rotation with the relay.
1
xcqseg-003
Relay (CA1aF-12V-N-5)_001
1
Relay (CA1aF-12V-N-5)
Inspection of Relay (CA1aF-12V-N-5)
Remove the power relay.
The normal measured resistance between
relay terminals 1 and 2 is about 80 Ω.
3
4
2
1
3
4
2
1
38jyg3-014
Inspection of Relay (CA1aF-12V-N-5)_001
■