Engine Start/Stop Circuit
There are four switches related to engine operation, each of which operates a relay in coordination
with each switch.
These are configured so that the following switches control multiple circuits.
Reel rotation switch
Seat switch
Proximity switch/Parking brake
Proximity Switch/Pump neutral
Operating outline of electrical circuits during engine operation
When engine operation conditions are satisfied, the relay/engine stop solenoid operates and the
fuel cut solenoid is activated along with it.
While the fuel cut solenoid is activated, fuel continues to be supplied to the engine to continue
operation of the engine.
If there is a malfunction such as the starter operating but the engine does not start, or the engine
starts but then stops, inspect and adjust the engine start/stop circuit
1.
2.
3.
4.
・