75
4.7
Calibrate unknown nozzle
Option 2.
In the cases that there is also no nozzle information distributed by the supplier we have to measure the four necessarily values
manual.
Step 1.
Start spraying on manual mode with 3 bar pressure
Step 2.
Measure 5 different nozzles spread over the total boom wide for 1 minute.
Example:
Nozzle 1
1,15 l
Nozzle 2
1,16 l
Nozzle 3
1,13 l
Nozzle 4
1,18 l
Nozzle 5
1,14 l
Step 3.
Calculate the average of the 5 nozzles
Example:
Average
1,152 l
Step 4.
Try out the min and max pressure. (Most of the time is this between the 2 and 8 bar.)
Step 5.
Fill in the values