93
5.4
Calibrating electronic level indicator
Step 6.
Switch off the agitation system. (This is to prevent movements in
the tank when the tank is almost empty)
Step 7.
Open the main valve on the FMC control box.
Step 8.
Check if the liters on the ASV screen starts to run.
Step 9.
Look inside the tank and switch of the main valve when the float is
touching the bottom.
(Advice take the box in your hand on the sprayer or ask an extra
person)
Step 10.
After switching of the main valve the following message will
appear
Step 11.
Confirm with the OK bottom
Extra added function:
When during the process something is gowning wrong. Push the
botton.
The calibration function has now stopped (sprayer is still spraying)
Switch the main valve and the control box and after 5 second
start it up again. The previous calibration value is now still inside
the box. And calibration steps can be activated again.