18
2.3.1
Flow sensor/Flow meter
Most of the sprayers are equipped with a flow sensor. The flow
meter measures the amount of spraying liquid from the regulator to
the spray line. Therefore the flow meter is always assembled
between the pressure regulator and the section valves.
There are 2 different models of flowmeters (which come in different
sizes)
Depending on the flow (ltr/min) the right size flowmeter has to be
chosen
Cable Colour
Contact
Brown
+ (12V)
White
signal
Green
-
The connection way and place is the same for all flowmeters
< 2014 model
>2015 model
< 2014 model
Size
Flow range L/min
¾”
7-70
1”
10-150
1½”
35-350
> 2015 model
Size
Flow range L/min
801
(3)
5-225
802
(5)
10-495