39
2.6
Connections Automatic steering system
•
The optional auto steering system is located in the Mini I/O
module or STC (Steering Controller)
•
It’s power and communication cables are connected in the
front splitterbox
FMC
Control box
CAN Cable
Power cable
Splitter
box
SHC Box
Hydraulic
Connectors
Connection
cable to water
valves and
hydraulic valves
Mini I/O
Boom in sensor cable
Communication/
Power cable (grey)
Steering
potentiometer
Valve
connectors
2.6.1
Splitterbox with steering system
The PCB has 3 possible connection slots for options
Wire plan for the Power & valve cable of the MINI I/O:
•
Wires 1 + 2 to the CAN Power Plus (+)
•
Wires 3 + 4 to the CAN Power Minus (-)
•
Wire 5 to the CAN High slot
•
Yellow/green wire to the CAN Low slot