94
5.5
Parameter and machine type information
Because the iXclean Comfort box is used on different machines
the parameters are very important.
Below you see a parameter list of the ASV (IxcleanComfort)
Parameter 25 (Tank level Filter)
This parameter can only be adjusted with the flashtool.
Ixter
Default 15 is OK
Ikarus S
Default15 is OK
Ixtrack
Has to be changed to 2. (Can only be done with
Flashtool)
Parameter 26 (Machine type)
This parameter is responsible for the flow schedule.
This parameter is linked to the tank size.
0 = Ixter (<2000L)
1 = Trailed (>2000L)
Parameter 27 (Reverse Sensor)
This parameter can only be changed with the flashtool.
Ixter 0
Ikarus S 1. (On ikarus S sensors works up side down)
Summary of Contents for TS-T
Page 5: ...1 2 EC connections 5 For more information please also check the inside of the PCB housing ...
Page 13: ...13 2 2 Standard Splitterbox connections ...
Page 17: ...17 2 3 SHC Box input connections ...
Page 35: ...35 2 4 8 Total overview SHC hydraulic section ...
Page 38: ...38 2 5 2 2 SHC boxes hydraulics 2 5 3 2 SHC Boxes water sections ...
Page 45: ...45 2 7 1 ASV system overview Fuse inside Fuse inside ...
Page 55: ...55 3 3 Cable and sensor test 3 3 1 Speed sensor machine and flow sensor test Metal ...
Page 56: ...56 3 3 Cable and sensor test 3 3 Locking sensor test ...