![Kverneland Electrical Control EC Operation Manual Download Page 34](http://html.mh-extra.com/html/kverneland/electrical-control-ec/electrical-control-ec_operation-manual_2012934034.webp)
Flowmate Control FMC
OPERATING INSTRUCTIONS
34
-
If the display 0.0 Ltr is shown, all the sections have been rinsed and a signal sounds.
The software of the system has now switched off all the sections.
-
Set the central switch for
Spraying
to
“Off”
. This turns the signal sound off.
Note:
The central switch for
Spraying
must be on
“Off”
before you can leave the screen
and return to
Main screen 1
or
Main screen 2
.
Remember that the conduit system has not yet been properly rinsed after the rinsing
function. Merely the spraying fluid has been displaced in the conduit system and removed.
The rinsing function must be done at least two or three times for proper rinsing of the
conduits.
§4.4 P
ARCEL MEMORY
From
Main screen 1
you have to press the arrow key 3 times to get to the
“Parcel memory”
screen (see fig. page 26).
The FMC spraying computer has 20 numbered memory spaced for storing the sprayed
area in hectares and the consumption in litres for 20 parcels of land.
In this way, the current accumulated values for area and quantity from
Main screen 2
can
be stored under a freely optional parcel number or be added to the values already available
in the memory.
To store the current accumulated values from
Main screen 2
proceed as follows:
-
Press the
OK key
, the parcel number flashes.
-
By using the arrow keys or select the parcel number and confirm with the
OK
key
, the signs
“+”
and
“C”
flash.
-
To delete the values already existing , firstly press the arrow key , then the
OK-
key
and then the arrow key .
-
Confirm with the
OK key
; the current accumulated values from
Main screen 2
are now
stored under this parcel number.
Summary of Contents for Electrical Control EC
Page 6: ...Spray computer FMC EC GZD EC OPERATING INSTRUCTIONS 6 ...
Page 15: ...System overview and assembly Flowmate Control FMC 15 Fig 4 Fig 5 6 9 5 7 6 8 ...
Page 19: ...Control box Flowmate Control FMC 19 Fig 1 4 1 5 3 3 6 2 Fig 2 8 9 7 ...
Page 21: ...Control box Flowmate Control FMC 21 Fig 4 11 Fig 3 10 ...
Page 37: ...Control box Flowmate Control FMC 37 ...
Page 57: ...Control box Electrical Control EC 57 25 Amp Fig 2 4 1 5 3 3 2 Fig 1 Fig 3 7 8 6 ...
Page 59: ...Control box Electrical Control EC 59 Fig 5 10 Fig 4 9 ...
Page 61: ...Electrical Control GZD EC Electrical Control GZD EC 61 ELECTRICAL CONTROL GZD EC ...
Page 65: ...Electrical Control GZD EC Electrical Control GZD EC 65 Fig 3 5 6 7 8 10 9 11 Fig 4 i 13 12 ...
Page 67: ...Electrical Control GZD EC Electrical Control GZD EC 67 Fig 5 14 Fig 6 5 6 7 8 10 9 ...