![Kverneland Electrical Control EC Operation Manual Download Page 32](http://html.mh-extra.com/html/kverneland/electrical-control-ec/electrical-control-ec_operation-manual_2012934032.webp)
Flowmate Control FMC
OPERATING INSTRUCTIONS
32
§4.3 F
ILLING AND RINSING FUNCTION
From
Main screen 1
you reach the
“Filling and rinsing function”
screen by pressing the arrow
key 2x, when the central switch
Spraying
is
"OFF"
(see fig. page 26).
Filling function:
Rinsing function:
To switch over to the other function, press the
OK key
, the
Spray tank
or
Water tap
symbol
flashes. With the arrow keys or switch to the other symbol and confirm with the
OK
key
.
The display shows the amount of fluid necessary to fill or to rinse the conduit system. The
amount of fluid depends on the length and the cross-section of the individual line sections
which have to be filled or rinsed and on the number of sections switched on. The necessary
data of the conduit system have already been programmed ex works and can be amended
if necessary in the
Service menu
.
§4.3.1 Filling function
With the help of the filling function, the conduit system can be filled with spraying fluid up to
the nozzles at the start of spraying work. This means that spraying fluid is available directly
at the nozzles at the start of spraying at the edge of the field and you can start immediately
when you have switched on.
Mode of procedure in filling the conduits:
-
Central switch for
Spraying
to
“Off”
.
-
Set all the valves on the sprayer to the
“Spraying”
position (see operating instructions
for sprayer).
-
All section switches to
“On”
. The display shows the amount of fluid needed in litres.
-
Central switch for
Spraying
to
“On”
. This initiates the filling process.
The through flow amount is used to calculate the residual amount of filling water and
displayed. Each filled section is automatically switched off by the computer.
Summary of Contents for Electrical Control EC
Page 6: ...Spray computer FMC EC GZD EC OPERATING INSTRUCTIONS 6 ...
Page 15: ...System overview and assembly Flowmate Control FMC 15 Fig 4 Fig 5 6 9 5 7 6 8 ...
Page 19: ...Control box Flowmate Control FMC 19 Fig 1 4 1 5 3 3 6 2 Fig 2 8 9 7 ...
Page 21: ...Control box Flowmate Control FMC 21 Fig 4 11 Fig 3 10 ...
Page 37: ...Control box Flowmate Control FMC 37 ...
Page 57: ...Control box Electrical Control EC 57 25 Amp Fig 2 4 1 5 3 3 2 Fig 1 Fig 3 7 8 6 ...
Page 59: ...Control box Electrical Control EC 59 Fig 5 10 Fig 4 9 ...
Page 61: ...Electrical Control GZD EC Electrical Control GZD EC 61 ELECTRICAL CONTROL GZD EC ...
Page 65: ...Electrical Control GZD EC Electrical Control GZD EC 65 Fig 3 5 6 7 8 10 9 11 Fig 4 i 13 12 ...
Page 67: ...Electrical Control GZD EC Electrical Control GZD EC 67 Fig 5 14 Fig 6 5 6 7 8 10 9 ...