![Kurzweil KDFX Manual Download Page 157](http://html1.mh-extra.com/html/kurzweil/kdfx/kdfx_manual_2011593157.webp)
System Exclusive Control of KDFX Parameters
Appendix C-3
Here are some examples of parameter values encoded into LSB and MSB:
Parameter value hexadecimal MSB LSB
(decimal)
255
00FF
01
7F
200
00C8
01
48
128
0080
01
00
127
007F
00
7F
0
0000
00
00
-1
FFFF
7F
7F
-50
FFCE
7F
4E
-128
FF80
7F
00
While this may seem complex, if you are using a dedicated controller to generate Sysex, you
may not need to worry about encoding parameter values, because the controller will do it for
you. For example, with one popular MIDI fader box, the following will give you control of
wet/dry mix for the Aux bus effect:
Function =
String
String =
F0 07 00 78 1B 2A 00 pr pr F7
Min =
0
Max =
100
Param format =
2Byte,7Bits,hi->lo
Note: Sysex disables FXMods
If a parameter is assigned to an FXMod, and you then modify it by Sysex control, the FXMod
will be temporarily disabled. It will re-establish itself the next time the Program or Setup is
selected.
Sysex and the rest of the K2500
Information about using Sysex with other aspects of the K2500 can be found in Chapter 11 of
the
K2500 Reference Guide
.
Summary of Contents for KDFX
Page 56: ...Inside KDFX Saving Studios and other objects 3 24...
Page 76: ...Real time Control of KDFX KDFX in Auto Mode 4 20...
Page 94: ...Using the Algorithms FXMod Diagnostic 5 18...
Page 104: ...Special Topics Using the Internal Effects 6 10...
Page 118: ...KDFX Objects KDFX Studios Appendix A 14...
Page 154: ...KDFX Controller Assignments in Programs Setups Appendix B 36...
Page 158: ...System Exclusive Control of KDFX Parameters Appendix C 4...
Page 164: ...Index 6...