The sensor “Blade monitoring” (B30) (1) is located on right-hand machine on the blade control
shaft.
• Loosen counter nut (2).
• Set the sensor (1) at a distance of
a=2 mm
to the lever (3) (lever swivelled up).
• Tighten counter nut (2).
The height of the sensor (1) can also be adjusted. Set the sensor so that it is detected as alive
in the sensor test.