Maintenance
280
Pos: 52.64.16 /Ü berschriften/Ü berschriften 3/P-T /S/Sensor B9/B10 Pr essdruck ei nstellen (F orti ma F 1250 (MC)/F 1600 (MC)) @ 395\mod_1446640889199_78.docx @ 2816239 @ 3 @ 1
16.10.3
Sensors B9/B10 Setting Baling Pressure (Fortima F 1250 (MC)/F 1600 (MC))
Pos: 52.64.17 /BA/Info-C enter /ALLE T er minals i n einem - ISOBU S, D elta, BET A II ( ab BJ 15/16)/ALLE T er minals/R undball enpressen/Sensor B9/B10 Pr essdruck ei nstellen_Bild_ALLE T ermi nals_F orti ma F @ 446\mod_1460644405027_78.docx @ 3040732 @ @ 1
FOR00050_1
3
5
4
IBT000289
OK
R
L
1
2
Fig. 239
Pos: 52.64.18 /BA/Info-C enter /ALLE T er minals i n einem - ISOBU S, D elta, BET A II ( ab BJ 15/16)/ALLE T er minals/R undball enpressen/Sensor B9/B10 Pr essdruck ei nstellen_Text- vor auss_ALLE T ermi nals_F orti ma F @ 446\mod_1460973715511_78.docx @ 3042715 @ @ 1
Prerequisite
– The bale chamber must be open and empty.
The respective sensor (3) must be set mechanically if the bar (2) is not inside the rectangle (1)
when the bale chamber is open and empty.
Pos: 52.64.19 /BA/Info-C enter /ALLE T er minals i n einem - ISOBU S, D elta, BET A II ( ab BJ 15/16)/ALLE T er minals/R undball enpressen/Sensor B9/B10 Pr essdruck ei nstellen_Text2_ALLE Ter mi nals_F orti ma F @ 395\mod_1446647806602_78.docx @ 2816955 @ @ 1
To do this:
• Loosen the sensor (3) and turn it in the oblong hole until the bar (2) is in the rectangle (1) of
the bar display.
An audio signal sounds if the bar (2) is inside the rectangle (1).
• If necessary, additionally move the sensor (3) in the oblong holes (5).
• Tighten the screw connections of sensor (3).
•
To save the value, select
key.
The icon
in the upper line indicates that the displayed value is saved.
Note
Saving is only possible when the bar (2) is inside the rectangle (1) of the bar display.