Foreign Terminal ISOBUS
131
Pos: 38.7 /Überschriften/Überschriften 2/F-J/I/ISOBU S Shortcut Button nicht vorhanden @ 362\mod_1439546689770_78.docx @ 2669647 @ 2 @ 1
10.2
ISOBUS Shortcut Button not Available
Pos: 38.8 /BA/Info-C enter/CC I-ISOBU S-Ter mi nal/M odul e für Bei pack/ISOBU S Short C ut Button/ISOBUS Shor t Cut Button nicht vor handen_Bild_F orti ma @ 384\mod_1444391899454_78.docx @ 2757933 @ @ 1
ISB
IBT000224
ISB
1
Fig. 96
Pos: 38.9 /BA/Info-C enter/CC I-ISOBU S-Ter mi nal/M odul e für Bei pack/ISOBU S Short C ut Button/Hinweis kei n ISOBUS Short C ut Button vor handen_nurFremdtermi nals @ 392\mod_1445961543425_78.docx @ 2805334 @ @ 1
If no ISOBUS Shortcut Button is available on ISOBUS terminals of other manufacturers, the
icon (1) is shown in the display. It is not possible to switch off machine functions via ISOBUS
Shortcut Button.
Pos: 38.10 /Ü berschriften/Ü berschriften 2/A-E/A/Abweichende Funkti onen zum KRON E ISOBU S T ermi nal @ 362\mod_1439551355532_78.docx @ 2669871 @ 2 @ 1
10.3
Deviating Functions from KRONE ISOBUS Terminal
Pos: 38.11 /BA/Info-Center/Iso-Bedienung/BigPack/Abweichende F unkti onen zum KR ONE ISOBUS-T ermi nal @ 380\mod_1443783589778_78.docx @ 2747187 @ @ 1
By means of ISOBUS operation unit, information and control functions of the machine are
provided on the display of the external ISOBUS terminal. The operation with an external
ISOBUS terminal is similar to the KRONE ISOBUS terminal. Before start-up, the functionality of
KRONE ISOBUS terminal is to be read in the operating instructions.
A significant difference to the KRONE ISOBUS terminal is the arrangement of icons and the
number of keys, which are determined by the selected external ISOBUS terminal.
The functions which deviate from KRONE ISOBUS terminal are described in the following.
Pos: 38.12 /BA/Info-Center/Iso-Bedienung/R undball enpressen/Abweichende Funkti onen_Fr emdter mi nal ISOBU S_Ballendurchmesser_Pressdr uck_F ortima @ 385\mod_1444821635546_78.docx @ 2762897 @ @ 1
On the foreign terminal ISOBUS, the values for bale diameter or baling pressure are set via
touch function, see provided operating instructions of terminal.
Pos: 38.13 /BA/Info-Center/Iso-Bedienung/Abweichende F unkti onen CCI_T erm Akustische Signale @ 365\mod_1441107598586_78.docx @ 2689306 @ @ 1
Note
Acoustic signals must be released by the terminal, if necessary (refer to operating instructions
of ISOBUS terminal manufacturer).
Pos: 39 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1