Maintenance
282
Pos: 52.64.26 /Ü berschriften/Ü berschriften 3/P-T /S/Sensor B14/B15 Ballenkammer geöffnet/Ballenauswurf (bei Ausführ ung T IM) @ 361\mod_1439454046118_78.docx @ 2667988 @ 3 @ 1
16.10.5
Setting Sensor B14/B15 Bale Chamber Opened/Bale Ejection (for “TIM” version)
Pos: 52.64.27 /Bei packs/R undball enpressen/T IM/Bedienung/Sensor B14 " Ball enkammer geöffnet" einstell en @ 282\mod_1406524462760_78.docx @ 2171475 @ @ 1
"B14 bale chamber open" sensor
When the bale chamber is fully open, the sensor must be alive. To do this:
• Position the sensor in the oblong hole so that the gap between sensor and metal is approx.
4 - 6 mm.
Pos: 52.64.28 /Bei packs/R undball enpressen/T IM/Bedienung/Sensor B15 " Ball enauswurf" ei nstellen @ 319\mod_1424089647940_78.docx @ 2468643 @ @ 1
Sensor “B15 bale ejection”
The sensor must be alive when the bale ejector is completely folded down. To do this:
• Position the signal sheet in the oblong hole so that the distance between sensor and metal
is approx. 4 - 6 mm.