
Initial operation
7
Gelenkwelle anpassen [Walterscheid]
7.5
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
75
Drilling lubrication borehole into inner guard tube
Ø 25 mm
1
2
3
4
5
BP000-401
Place the inner guard tube (2) next to the outer section tube (4) so that the slide ring lock (5)
is in alignment with the opening (1).
Mark the position (3) of the grease nipples on the inner guard tube (2).
Drill a borehole Ø 25 mm in the inner guard tube (2) and deburr it.
Mounting outer guard tube
7
2
6
1
2
1
2
5
3
4
I
BP000-403
Push the outer guard tube (7) onto the inner section tube and align it so that the stop (6) of
the slide ring and the opening of the guard funnel (2) are in alignment.
Turn the collar (1) until you can feel a stop, refer to detail (I).
Mount the 3 screws (5).
Use a screwdriver (3) to pull the collar (1) over the locks (4) of the guard funnel (2)