23
Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
306
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
Possible cause
Remedy
The sensor wiring is faulty.
Check sensor and wiring for damage,
.
522114-
B17
Sensor B17 “Baling flap pressure“
Possible cause
Remedy
FMI 2: The data is not permitted.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522115-
B12
Sensor B12 “Bale ejection“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522116-
B14
Sensor B14 “Bale ejector“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522117-
B15
Sensor B15 “Star wheel“
Possible cause
Remedy
FMI 2: The data is not permitted.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522118-
B23
Sensor B23 "Pick-up position"
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.