Malfunction, cause and remedy
23
Malfunctions electrics/electronics
23.1
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
313
Possible cause
Remedy
The wiring of the actuator is
faulty.
Check actuator and wiring for damage,
.
522304-
K02
Actuator K02 „Retract pilot valve“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522305-
K01
Actuator K01 „Extend pilot valve “
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522306-
K07
Actuator K07 „Blade cassette annular surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522307-
K08
Actuator K08 „Blade cassette annular surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522308-
K09
Actuator K09 “Release baling flaps“