7
Initial operation
7.5
Gelenkwelle anpassen [Walterscheid]
74
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
Shortening guard tubes and section tubes
X+5cm
X+5cm
X+5cm
X+5cm
1
2
3
4
BP000-396
Mark the determined dimension X plus 5 cm on the guard tubes (2, 3) and on the section
tubes (1, 4).
NOTE:
In order to protect the section tube from chips, stuff a damp cloth in the section tube
when using an angle grinder.
Shorten the guard tubes (2, 3) and the section tubes (1, 4) at right angles on the placed
markings, deburr from outside and inside and remove the chips.
Mounting seal
1.
2.
3.
Ø 6 mm
4.
1
2
2
5.
3
BP000-400
INFORMATION:
Ensure that the boreholes for the seal (1) are in alignment with the existing
grease nipples.
Heat the outer section tube at the point on the opposite side.
Mark out the borehole for the seal (1) 7 mm away from the end of the tube.
Drill a borehole Ø 6 mm into the section tube through both walls and deburr from inside and
outside.
Slide the seal (1) onto the section tube and mount with 2 screws (2).
Æ
The screws must not protrude into the inside of the tube.
Grease the inner section tube (3) from the outside.