23
Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
300
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
522054-
6
Upper twine 6
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
On the upper twine, the min-
imum twine length has benn
exceeded during packer feed.
Have the sensor adjusted.
522057-
Knotter monitoring
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
The knotter shaft has not ro-
tated within one plunger
stroke.
Have the sensor adjusted.
522058-
M1
Knotter motor
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
The knotting process has not
been finished withing two
plunger strokes.
Check the electrical system of the knotter motor.
Check the mechanics in the area of the knotter triggering.
Have the sensor adjusted.
522060-
Packer
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The packer is blocked.
Stop the traction drive immediately.
Reduce the PTO speed until the crop blockage has been
removed.
Have the sensor adjusted.
522061-
OFF
Self-steering axle
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
Timeout for locking/releasing
the steering axle.
Check the hydraulic connection.
Check the sensor and replace it, if necessary.
522062-
Pick-up
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The pick-up is blocked.
Check the mechanics.