Settings
16
Checking/setting Variable Filling System (VFS) 16.20
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
229
Correction
Set the setting screw (13) until the dimension is
Y=
5 – 8 mm between the centre of the
grooved ball bearing and the tripping ratchet tip (6).
Make sure that the grooved ball bearing rets on the tripping ratchet.
Æ
If dimension Y cannot be set, check and set if required the absorbing unit,
Set the threaded rod (9) until the sensing rake (11) has a dimension of
X=
5 – 10 mm to the
edge of the packer tray (12).
16.20.3
Setting the zero adjuster
BP000-235
ü
The Variable Filling System (VFS) is in zero position,
.
ü
The machine is shut down and safeguarded,
.
Release the spring (2).
Loosen the screw (23).
Swivel the zero adjuster (3) manually upwards.
Swivel the cam disc (5) manually as far as it will go towards (I) and hold it there.
Swivel the zero adjuster (3) downwards and turn the eccentric (22) until the roll (4) rests
against the lower area (III) of the zero adjuster.
Tighten the screw (23).
Release the cam disc (5).
ð
The roll (4) of the zero adjuster roll swivels in the upper area (II) of the zero adjuster.
.
Set the rubber buffer at the zero adjuster,
Checking the clearance of the ratchet
.
Turn the flywheel manually in working direction (
) until the roll (4) engages
again in the zero adjuster (3).
Make sure that tripping ratchet (6) does not move during the whole process.