5.4.3 Managing your files from your pc
The converter can be connected to a pc with a USB cable (option). The memory of the converter is
shown in the explorer treeview on your pc in a similar way as a memory stick.
The site files are stored in \pcf\data\configuration (as .XML files).
The log files are stored in \pcf\data\log (as .log files).
You can copy the configuration and log files to your pc for backup and storage. You can copy
configuration files that were created with the UFC 400 P emulation software on your pc. You can
copy log files that were created during earlier data logging sessions on a UFC 400 P to the UFC
400 P.
When the converter is connected to your pc you can not convert log files to CSV format on the
converter. This will only work with a memory stick connected to the converter.
Emulation of the signal converter operation on a pc
Emulation of the signal converter operation on a pc
Emulation of the signal converter operation on a pc
Emulation of the signal converter operation on a pc
On the memory stick provided with the OPTISONIC 6400 a file "win32.zip" is provided. If you unzip
this file to the harddisk of your pc you can run the signal converter user interface on your pc. To
start this program select \win32\pcf.exe. With this program you can load site files, change
settings and store them. You can also convert logged data to CSV format. The CSV file will be
stored in the \win32 folder. With this program of course there is no measurement function
available.
CAUTION!
Do not create / change other files than the ones mentioned. Do not delete other files or folders