Basic Readout, #700-1600-240 

General Purpose Readout, #700-1600-245 

(6 extra keys and more features) 

 

General Purpose Enhanced, #700-1600-246 

(firmware version ends with “C”, even more 
features)

 

 

950 Series Readout, #700-1600-M50 

(10pin input connector) 

Note: This guide applies to ProScale readouts with Firmware Version 
4.000 (firmware version is displayed on power-up).  

If your readout has a different firmware version, this manual should not 
be used. Consult factory for assistance.

 

 

 

ProScale

® 

 

Flush Mount 

Readouts

 

 

QUICK-START GUIDE 

Summary of Contents for ProScale 950 Series

Page 1: ...with C even more features 950 Series Readout 700 1600 M50 10pin input connector Note This guide applies to ProScale readouts with Firmware Version 4 000 firmware version is displayed on power up If y...

Page 2: ...Pr2 Reading Direction __________________ Parameter Pr13 Linear Multiplier __________________ Parameter Pr14 Compatibility __________________ If your digital scale has this pattern set Parameter 14 to...

Page 3: ...These Readouts may be mounted several ways 1 Using Velcro or double sided tape 2 Use the 3 punch out holes inside case Mount readout to machine panel using 6 or M4 flathead screws 3 Use any or all of...

Page 4: ...e upper right and lower left corners of the readout Lift the cover off Remove the old battery and install a new battery noting the proper orientation Replace the cover and screws External Power These...

Page 5: ...increased or decreased c If the displayed value got larger smaller and this IS correct for your installation no further steps are needed d If the displayed value got larger smaller and this IS NOT cor...

Page 6: ...What happens if a KEY IS HELD DOWN Key Action ON OFF Nothing UNITS Nothing PLUS The displayed value increases faster each 2 seconds DATUM After 4 seconds the battery voltage is displayed After 7 secon...

Page 7: ...s readout back to ABS mode SEND The currently displayed value is sent to the SPC port None F1 An offset value is applied If offset feature is enabled in the programming menu Also used to store compens...

Page 8: ...LUS MINUS or DATUM keys are pressed See page 6 for key combination to turn this off The readout s display is frozen When this feature is enabled press F4 key to turn on off Monitor mode drift alarm is...

Page 9: ...readout will show 5 5 16 and turn on the 200 indicator Minus sign Turns on when a negative value is displayed Battery level indicator When all 3 bars are lit your battery is good When only bottom bar...

Page 10: ...o add functionality These include Mode feature Function Offsets Allows the readout to track up to 5 reference positions at the same time Monitor Allows the readout to watch for unintended motion drift...

Page 11: ...on then Pr1 3 Release the UNITS key 4 After a moment the value for Pr1 will display Change the parameter value using the PLUS or MINUS keys Default the parameter value using the DATUM key Advance to...

Page 12: ...ue 0 000 Pr29 Upper limit value 5 000 inches Pr30 Offset additions to use 0 None Pr31 First offset value 0 5000 inches Pr32 Second offset value 2 0000 inches Pr33 Third offset value 3 0000 inches Pr34...

Page 13: ...eds to be replaced immediately Check programming values after new battery is installed LOCK The keypad is LOCKed but an attempt was made to change the calibration Unlock keypad to fix see page 6 P LOC...

Page 14: ...readout Switching power supply Part number 550 2003 001 Provides 15VDC power to the readout Wireless Data Transmitter Part number 700 1037 001 Transmits measurement values to a remote computer using Z...

Page 15: ...stem ProKit 590 is available in measuring lengths up to 190 inches 4 8m SPC output comes standard Wireless data transmitter is available ProTable SA is a self contained single axis measuring table QC...

Page 16: ...ProScale LCD Readouts version 4 Page 16 of 16 Thank you for choosing a ProScale Product IT WAS PROUDLY MADE IN THE USA Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 1 828 654 7...