2
INSTALLATION
28
OPTISONIC 6300
www.krohne.com
06/2019 - 4005857501 - QS OPTISONIC 6300 v2 R01 en
2.10.2 Wall mounting
Mounting the field version (F) on the wall
1
Prepare the holes with the aid of the mounting plate.
further information refer to
Mounting plate of field housing
on page 55.
2
Use the mounting material and tools in compliance with the applicable occupational health
and safety directives.
3
Fasten the housing securely to the wall.
4
Screw the signal converter to the mounting plate with the nuts and washers.
Figure 2-25: Wall mounting of the field housing
Figure 2-26: Mounting multiple devices next to each other
a
t
600 mm / 23.6"
b
t
250 mm / 9.8"