2
INSTALLATION
20
OPTISONIC 6300
www.krohne.com
06/2019 - 4005857501 - QS OPTISONIC 6300 v2 R01 en
Mounting the cover
Mounting the cover
Mounting the cover
Mounting the cover
•
1
put back the cover, vertically onto the rail
•
2
slide cover sidewards and close housing
•
3
secure the cover on the rail housing by turning screw on the side
2.9.2 Installation of solid contact material
Solid contact material cause lower signal quality compared to contact grease. The signal
strength will be stable over time and therefore lower start up signal strength is acceptable. In
case of insufficient signal strength only contact grease can be used.
Installation and optimization should first be done using contact grease. After finding the optimal
position use the click and turn mechanism to install the pads. Apply a thin layer of grease on
both sides of the pad and place it on the transducer surface. Click and turn the rail back on the
pipe.
INFORMATION!
Not applicable for stainless steel / XT versions. These are delivered without cover.