4.4 Mechanical installation for large version
•
Secure by turning screws clockwise.
INFORMATION!
You need a calculator, measuring band and pen & paper to install a large version.
CAUTION!
Make sure that you mount the rail parallel to the pipe. Mount the fixing units and the cable box as
shown below.
Figure 4-4: Mounting large version rail
1
Pull the metal strap through the upper slit of the UP rail.
2
Take the metal strap around the pipe (45...60
°
).
3
Push the end of the metal strap into the lower slot of the fixing unit.
4
Take the other side of the metal strap around the pipe to the fixing unit.
5
Mount the cable box (only for the downstream metal strap).
6
Push the metal strap through the upper slot of the fixing unit.
7