INSTALLATION
2
17
OPTISONIC 6300
www.krohne.com
06/2019 - 4005857501 - QS OPTISONIC 6300 v2 R01 en
2.8.9 Pipe diameters and sensor construction
Overview version and measuring modes
2.8.10 Pipe and media parameters
Figure 2-18: Measuring modes
1
Z-mode
2
V-mode
3
W-mode
4
X-mode
Rail version
Rail version
Rail version
Rail version
Diameter range
Diameter range
Diameter range
Diameter range
Preferred measuring
Preferred measuring
Preferred measuring
Preferred measuring
modes
modes
modes
modes
Possible measuring
Possible measuring
Possible measuring
Possible measuring
modes
modes
modes
modes
Small
DN15...100 / 0.5...4"
< DN25: W-mode (4
traverses)
Small: V mode
t
DN25: V-mode (2
traverses)
Medium
DN50...400 / 2...16"
V-mode (2 traverses)
DN200...1250 / 8...50"
X-mode (2 x 1 traverses)
Large
DN200...4000 / 8...160"
Z-mode (1 traverse)
Large: V mode (2
traverses)
Table 2-1: Version and preferred measuring mode
INFORMATION!
Detailed databases of most pipe and media parameters are on the supplied CD.