Kongsberg AIS 200 Installation Manual, rev. 2
Software setup procedure
5.4
Configuration through setup file
When changes are done directly in the setup file, the file has to be transferred to an external
computer first. Then the file is edited and transferred back to the AIS 200. To make this
transfer it is necessary to use an ftp-software (ftp-file transfer protocol).
5.4.1
Network parameters
When connecting the AIS 200 to a network, the IP address, Gateway, Subnet mask and server
name must be set. When leaving Seatex the parameters are set for internal use at Seatex and
must be changed when used in another network. The LAN broadcast address is used to
configure a client subnetwork or a single client which should receive PI data on LAN.
AIS_IP_ADDR
10.0.21.25 ! IP Address space between 10.0.21.60-66
AIS_SERVER_NAME
AIS_TR200 ! Server Name
AIS_LAN_BRC_ADDRESS
10.0.21.255 !Broadcast address
AIS_LAN_BRC_PORT
4711 !Broadcast port
AIS_SUBNET_MASK
255.255.255.0 !Subnet mask
AIS_GATEWAY
10.0.21.1 !Gateway
The default port address for the PI LAN is 4711 or 4712. 4711 is for listening to UDP and
4712 is for sending commands over TCP.
5.5
Message types
The AIS system supports different messages on the VHF data link and on the PI and LAN
interface.
Kongsberg AIS 200
Messages 1, 2, 3, 5, 6,
7, 8, 11, 12, 13, 14, 15
Messages 1 through 22
VDM, VDO, ALR, TXT,
ABK, PSTX, VSD, SSD,
LR1-3, LRI, LRF
ABM, ACA, AIR, BBM
VDL interface
PI & LAN
interface
Figure 1 Message flow at VDL and PI serial/LAN interface
40
Summary of Contents for AIS 200
Page 1: ...Kongsberg AIS 200 Installation Manual Manual part no A103 03 Issued 2005 05 09...
Page 2: ...Blank page...
Page 4: ...Blank page IV...
Page 6: ...Blank page VI...
Page 14: ...Kongsberg AIS 200 Installation Manual rev 2 Introduction Blank page 4...
Page 26: ...Kongsberg AIS 200 Installation Manual rev 2 Technical specifications Blank page 16...
Page 54: ...Kongsberg AIS 200 Installation Manual rev 2 Software setup procedure Blank page 44...
Page 58: ...Kongsberg AIS 200 Installation Manual rev 2 Maintenance Blank page 48...
Page 77: ...Kongsberg AIS 200 Installation Manual rev 2 Appendix B Digital interface IEC 61162 1 67...
Page 113: ...Kongsberg AIS 200 Installation Manual rev 2 Appendix D Troubleshooting form Blank page 103...
Page 115: ...Kongsberg AIS 200 Installation Manual rev 2 Appendix E Optional VHF antenna Blank page...