5.2 Dealing with plate jams
Error
Code
Message
Appropriate action
27110
USB was disconnected during image transmis-
sion .
Connect USB .
Image transmission will start after connection .
Confirm USB cable connection. Once connection is estab
-
lished, image data transmission will resume .
Error
Error
Code
Message
Appropriate action
24000
Connection failed .
Check all LAN connections .
Reboot the system if it is not recovered .
If the Image processing controller server has not started
up yet, wait for it to do so .
If the Image processing controller server has started up,
make sure network devices (HUB, cables, etc .) are work-
ing properly between the Image processing controller
client connected to the reader, and the Image processing
controller server . (Also remove and reconnect the cable
connector .)
If the error is not fixed, restart the Image processing con
-
troller PC .
25000
Connection with server PC failed .
Check all LAN connections with server .
Reboot the system if it is not recovered .
Make sure network devices (HUB, cables, etc .) are work-
ing properly between the Image processing controller
client connected to the reader, and the Image processing
controller server . (Also remove and reconnect the cable
connector .)
If the error is not fixed, restart the Image processing con
-
troller PC .
25200
Data transmission failed by LAN disconnection .
Check all LAN connections with server .
Re-send data after connection recovery
Make sure network devices (HUB, cables, etc .) are work-
ing properly between the Image processing controller
client connected to the reader, and the Image processing
controller server . (Also remove and reconnect the cable
connector .)
By returning to the proper connection status, image data
will be retransmitted . (However, this will only occur when
Image processing controller and reader operations are
uninterrupted . If power is turned OFF, or operations are
halted, image data will not be retransmitted .)
If the error is not fixed, restart the Image processing con
-
troller PC . (Image data will be lost in this case .)
25300
Data transmission failed by LAN disconnection .
Check all LAN connections with server .
Reboot the system if it is not recovered .
Make sure network devices (HUB, cables, etc .) are work-
ing properly between the Image processing controller
client connected to the reader, and the Image processing
controller server . (Also remove and reconnect the cable
connector .)
If the error is not fixed, restart the Image processing con
-
troller PC .
Summary of Contents for REGIUS SIGMA2
Page 1: ...EN 05 0197 Operation Manual DIRECT DIGITIZER REGIUS SIGMA2...
Page 2: ......
Page 5: ...5 Introduction...
Page 10: ...10...
Page 21: ...21 Chapter 2 Product Outline An explanation of the device s features and functions...
Page 27: ...27 Chapter 3 Reader Operation An explanation on how to operate this device...
Page 35: ...35 Chapter 4 Cassette Plate Operation An explanation on cassette and plate handling...
Page 45: ...45 Chapter 5 Troubleshooting An explanation on how to deal with errors when they occur...
Page 62: ...62...
Page 70: ...70...
Page 71: ...71 Appendix A list of device specifications etc...
Page 74: ...74...
Page 75: ......
Page 76: ...A5ERBA01EN05 2015 08 31 JD...