3.2 Explanation of components
Operation
3-18
WA500-6H – VEAM430100
1. Brake oil pressure caution lamp
This lamp (1) lights up when the brake oil pressure goes below
the specified value.
During checks before starting (when the starting switch is turned
to the ON position but the engine is not started), the brake cir-
cuit is not actuated while the engine is stopped, so the brake oil
pressure caution lamp and central warning lamp do not light up
and the alarm buzzer does not sound.
During operation (engine running)
If the brake oil pressure goes down during operation, the brake
oil pressure caution lamp and central warning lamp light up and
the alarm buzzer sounds intermittently.
At the same time, “E03 CHECK RIGHT NOW“ is displayed on
the character display, so stop the machine immediately, then
stop the engine and carry out inspection.
When the brake oil pressure caution lamp lights up during oper-
ation, if the oil pressure drops further, the parking brake is auto-
matically actuated.
Immediately after the engine starts, the accumulator is in the
process of storing pressure, so the brake oil pressure caution
lamp lights up, but the central warning lamp does not light up
and the alarm buzzer does not sound.
Do not move the machine until the brake oil pressure caution
lamp goes out. Keep the parking brake applied.
2. Engine oil pressure caution lamp
This lamp (2) lights up to warn the operator that the engine lubri-
cating oil pressure has dropped.
During checks before starting (starting switch at the ON position,
engine stopped) the lamps are lighted up, and when the engine
is started, the lamps go out.
During operation (engine running)
If the engine lubricating oil pressure goes down during opera-
tion, the engine lubricating oil pressure caution lamp and central
warning lamp light up and the alarm buzzer sounds intermit-
tently.
At the same time, “E03 CHECK RIGHT NOW“ is displayed on
the character display, so stop the machine immediately, then
stop the engine and carry out inspection.
GK032093
GK032094
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...